Binder

The pick surface that connects component inputs to page data, live feeds and sheets.

When a binding does not paint.

SymptomLikely cause
Clicking a key does nothingNo slot is armed — the header shows the idle text rather than “Connecting …”.
Visibility is invertedA binding onto hidden reads truthy as hidden. A toggle labelled “visible” needs the invert flag; the editor sets it for visibility paths.
The field paints but flickersTwo writers on one path, or a unit writing every tick. Check the unit report.
Blank on air, fine in the editorA guard is holding — onMissing of hold, blank or zero decides what a missing value paints.
A feed field is greyed outThat poller is disabled. Enable it in Units.

Truthiness for a hidden binding is deliberately generous: true, 1, "1", "true" and "on" read as true; false, 0, "0", "false", "off", empty string and null read as false. Anything else falls back to JavaScript truthiness.